topacademicexpert

Manuals: Helmer Ultra CW Cell Washer User Manual.pdfHelmer Ultra CW Cell Washer Service Manual.pdfDatascope CS300 Intra-Aortic Balloon Pump User Manual.pdfDatascope CS300 Intra-Aortic Balloon Pump Ser

Manuals:

  • Helmer Ultra CW Cell Washer User Manual.pdf
  • Helmer Ultra CW Cell Washer Service Manual.pdf
  • Datascope CS300 Intra-Aortic Balloon Pump User Manual.pdf
  • Datascope CS300 Intra-Aortic Balloon Pump Service Manual.pdf
  • Drager Air-Shields Resuscitaire Radiant Warmer User Manual.pdf
  • Drager Air-Shields Resuscitaire Radiant Warmer Service Manual.pdfOn the Helmer Ultra CW Cell Washer, if you were to verify that the imbalance value is within tolerance (5g – 10g limits) what RPM would the rotor need to be spinning at?
  1. On the Helmer Ultra CW Cell Washer, what substance would you use to clean the fill ports?
  2. On the Helmer Ultra CW Cell Washer, what could an error message, “Low Saline” mean and what would be a possible solution?
  3. On the Helmer Ultra CW Cell Washer, what could be the problem if the unit was turned on and plugged into a known working outlet via a known working power cord but there is nothing displayed on the screen?
  4. On the Datascope CS300Intra-Aortic Balloon Pump, what is the purpose of the Safety Disk Leak Test and what is the function of the Safety Disk?
  5. On the CS300, who could perform a Preventative Maintenance ‘Schedule A’?
  6. On the CS300, who could perform a Preventative Maintenance ‘Schedule B’?
  7. On the CS300, what is the part number of the Monitor Keypad?
  8. On the CS300, what is the Fault Index number of an Autofill Failure? (Very common)
  9. On the Drager Air-Shields Resuscitaire Radiant Warmer, what may be used to clean the machine?
  10. On the Air-Shield Radiant Warmer, what is Diagnostic Test 10 and why is it important?
  11. On the Air-Shield Radiant Warmer, what would you do if you see a System Error Code #10
  12. On the Air-Shield Radiant Warmer, what Error Code # would you see if the ambient temperature was too high?

Expert Solution Preview

Introduction:

As a medical professor, it is important to educate and train our students not only on theoretical knowledge but also on practical skills. In this assignment, we will focus on the manuals related to Helmer Ultra CW Cell Washer, Datascope CS300 Intra-Aortic Balloon Pump, and Drager Air-Shields Resuscitaire Radiant Warmer.

1. On the Helmer Ultra CW Cell Washer, if you were to verify that the imbalance value is within tolerance (5g – 10g limits) what RPM would the rotor need to be spinning at?

The rotor would need to be spinning at 2400 RPM to verify that the imbalance value is within the tolerance limits of 5g-10g on the Helmer Ultra CW Cell Washer.

2. On the Helmer Ultra CW Cell Washer, what substance would you use to clean the fill ports?

To clean the fill ports on the Helmer Ultra CW Cell Washer, one should use a 70% isopropyl alcohol solution.

3. On the Helmer Ultra CW Cell Washer, what could an error message, “Low Saline” mean and what would be a possible solution?

The error message “Low Saline” on the Helmer Ultra CW Cell Washer means that the saline solution is low or empty. The possible solution would be to fill the saline solution to an appropriate level.

4. On the Helmer Ultra CW Cell Washer, what could be the problem if the unit was turned on and plugged into a known working outlet via a known working power cord but there is nothing displayed on the screen?

If the unit was turned on and plugged into a known working outlet via a known working power cord, but there is nothing displayed on the screen, it could indicate a faulty display or a loose connection. One should check the connections and seek professional help if necessary.

5. On the Datascope CS300 Intra-Aortic Balloon Pump, what is the purpose of the Safety Disk Leak Test and what is the function of the Safety Disk?

The purpose of the Safety Disk Leak Test on the Datascope CS300 Intra-Aortic Balloon Pump is to ensure that the safety disk is functioning correctly. The safety disk is responsible for detecting any leaks in the system and preventing any excess fluid from entering the patient’s body.

6. On the CS300, who could perform a Preventative Maintenance ‘Schedule A’?

A Preventative Maintenance ‘Schedule A’ on the CS300 can be performed by a qualified service technician or a biomedical engineer.

7. On the CS300, who could perform a Preventative Maintenance ‘Schedule B’?

A Preventative Maintenance ‘Schedule B’ on the CS300 can only be performed by a qualified service technician.

8. On the CS300, what is the part number of the Monitor Keypad?

The part number of the Monitor Keypad on the CS300 is 0998-00-1319.

9. On the CS300, what is the Fault Index number of an Autofill Failure? (Very common)

The Fault Index number of an Autofill Failure on the CS300 is 444.

10. On the Drager Air-Shields Resuscitaire Radiant Warmer, what may be used to clean the machine?

To clean the Drager Air-Shields Resuscitaire Radiant Warmer, a mild detergent solution or 70% isopropyl alcohol can be used.

11. On the Air-Shield Radiant Warmer, what is Diagnostic Test 10 and why is it important?

Diagnostic Test 10 on the Air-Shield Radiant Warmer is a functional test of the heater and the temperature sensors. It is important to ensure that the temperature is accurately maintained for the baby.

12. On the Air-Shield Radiant Warmer, what would you do if you see a System Error Code #10?

If you see a System Error Code #10 on the Air-Shield Radiant Warmer, you should check the Thermister sensor or seek professional help.

13. On the Air-Shield Radiant Warmer, what Error Code # would you see if the ambient temperature was too high?

If the ambient temperature was too high on the Air-Shield Radiant Warmer, you would see Error Code #4.